| Type |
|
Pilot Operated Check Valve, Size 2 |
|
|
| Designation |
|
Pilot-operated check valve |
|
|
| Design |
|
Guided poppet / seat |
|
|
| Mounting method |
|
Stack mounting |
|
|
| Size |
|
ISO 4401-02-01 interface |
|
|
| Max operating pressure |
|
250 bar in P, A, B and T 160 bar in T if used with WEDA-...-4 directional valve |
|
|
| Max flow rate |
|
25 l/min |
|
|
| Flow direction |
|
See symbols |
|
|
| Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524 |
|
|
Hydraulic fluid temperature range |
|
- 20°C ... + 60 °C |
|
|
| Viscosity range |
|
10...300 mm²/s (cSt) |
|
|
| Minimum fluid cleanliness |
|
18/14 to ISO 4406 / CETOP RP70H 8...9 to NAS 1638 |
|
|
| For mer informasjon |
|
Klikk her --- Datablad --- Oversikt |
|
|