| Type |
|
Proportional 3−Way Pressure−Reducing Cartridge, Size 2...5 |
|
|
| Designation |
|
Proportional 3−way pressure−reducing cartridge |
|
|
| Design |
|
Direct acting, electrically operated |
|
|
| Mounting method |
|
Push−in cartridge, 4 mounting bolts M4x50 |
|
|
| Size |
|
Nominal size 2...5, cavity type AG |
|
|
| Cavity type thread |
|
|
|
|
| Max operating pressure |
|
70 bar, pressure range "055" - Standard model 50 bar, pressure range "040" - Standard model 40 bar, pressure range "030" - Standard model 30 bar, pressure range "020" - Standard model 20 bar, pressure range "011" - Standard model
100 bar, all pressure ranges - Model "H" |
|
|
| Max flow rate |
|
15 l/min |
|
|
| Flow direction |
|
See symbols |
|
|
| Hydraulic fluid |
|
Mineral oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 70 °C |
|
|
| Viscosity range |
|
15...380 mm²/s (cSt), recommended 20...130 mm²/s (cSt) |
|
|
| Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 : 1999 |
|
|
| For mer informasjon |
|
Oversikt |
|
|