| Type |
|
Proportional Pressure−Reducing Cartridge, Size 10 |
|
|
| Designation |
|
Proportional pressure−reducing cartridge |
|
|
| Design |
|
Seated pilot, spool−type main stage |
|
|
| Mounting method |
|
Screw−in cartridge M24 x 1,5 |
|
|
| Size |
|
Nominal size 10, cavity type DD |
|
|
| Cavity type thread |
|
|
|
|
| Max operating pressure |
|
315 bar in ports A, B (for 350 bar, consult BUCHER) No back−pressure in port Z |
|
|
| Max flow rate |
|
120 l/min |
|
|
| Flow direction |
|
See symbols |
|
|
| Hydraulic fluid |
|
Mineral oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 70 °C |
|
|
| Viscosity range |
|
15...380 mm²/s (cSt), recommended 20...130 mm²/s (cSt |
|
|
| Minimum fluid cleanliness |
|
18/16/13 to ISO 4406 : 1999 |
|
|
| For mer informasjon |
|
Klikk her --- Oversikt |
|
|